Hi Experts,
We have the following situation.
We have a material which is Batch managed and has Batch-Specific Units of measure. We did the following steps for configuration:
- Tx. CUNI
- Created Batch-Specific UM: TUB (TUBE)
- Created Base UM (or we can use a Standard UM): M (Meters)
- Created the Characteristic UM: M/TUBE (Meters/Tube)
- Activated Batch-Specific Units of Measure.
- Defined the Batch-Specific UM: TUB.
- Defined calculation of Base Quantity from Product Quantity.
- Tx. CT04 Created characteristic with values.
- Tx. CL01 Created class.
- Created Split valuation.
- Created a new material and assigned the Valuation Category X and the conversion factor in Additional Data > Proportion/prod.unit: the default conversion factor is 5.80/1.
- Tx. MSC1N Created two different Batches with different values (conversion factor).
- Batch 5.80 Meters: 5.80/1
- Batch 3.00 Meters: 3.00/1
In stock I have:
- Batch 5.80 Meters 1 TUB or 5.80 M
- Batch 3.00 Meters 1 TUB or 3.00 M
Until this point everything is fine:
- Conversion factor is working for each specific batch.
- The value of the stock is correct: 1 TUB of Batch 5.80 Meters is almost twice as expensive as 1 TUB of Batch 3.00 Meters.
We then create a Maintenance Order and release it requiring:
- 2 TUB Batch 5.80 Meters (This will generate a Purchase Requisition when MRP runs)
- 1 TUB Batch 3.00 Meters
When the system does the reservation, instead of reserving a total of 14.60 meteres ( 5.80 x 2 + 3.00 x 1 ) it reserves 17.40 meters. It is as if the system was converting the 1 TUB of Batch 3.00 Meters into 5.80 meters instead of 3.00 meters.
Any ideas why when the order requires 1 TUB Batch 3.00 Meters the system is not using the Batch 3.00 Meters conversion factor (3.00/1) for the material reservation and is instead using the default conversion factor (5.80/1) ?
Thank you in advance.
Best Regards,
Leonidas Oyaga